MOMA无线技术 Published at: 2025-11-10

How to perform IP cascading for2 sets of Solidcom M1 pro Hub


For Solidcom M1 pro

1. Connection
Connect the two main units with standard network cables to[RJ45]The back of the main unit has [2 RJ45] ports, any one can be connected, and the maximum length of the network cable can be[100 meters]
2. Master-slave settings
After connecting the network cables between the two main units, you need to enter the [Master-Slave Switching] menu of the main unit to set the [Master-Slave Device Switching], generally the first main unit is set as[Master Device], the second main unit is set as[Slave Device] => [Scan] => [Select Master Device IP]That's it.
It should also be noted that in the [Network Settings] [IP Address Settings] of both main units, you need to set[Automatically Obtain IP]to[Off]
Hub❶
Enter the [Network] menu, automatically obtain IP address [Off]
Enter the [Master And Slave menu], select [Master Device]
[Network] settings
Hub❷
Enter the [Network] menu, automatically obtain IP address [Off]
Enter the [Master And Slave menu] select [Slave Device] [Scan]
[Network] Settings


After entering [Network], the IP address of the [Master Device] will appear, select [IP Address] with the directional keys and confirm.

Submit Feedback